Quick Drying Modified Alkyd Based Primer Supplier in China
Quick Drying Modified Alkyd Based Primer paint coating manufacture Shenzhen China  
Home About Us Products Contact Us

 

 




Honest Joy Coating & Paint
Alkyd coating

Urethane-Modified Alkyd Primer
Urethane Alkyd Enamel
Urethane Alkyd Based Toopcoat
Epoxy Ester Modified Alkyd Primer

Superior Quality Alkyd Glaze
Speedy-Dry Alkyd Enamel
Silicone Modified Alkyd Enamel
Semi-Transparent Organic Solvent Stain
Rust-Inhibitive Patented Acrylic Modified Alkyd Enamel
Quick-Drying Styrenated Alkyd Paint

Alkyd Urea Clear Coat
Transparent Modified Alkyd Sealer
Alkyd Semigloss Finish
Transparent Modified Alkyd Sealer
Quick Drying Modified Alkyd Based Primer
Rust Preventing Primer
Quick Drying Clear Urethane Alkyd Varnish
Versatile Finish Coat Based On Long Oil Alkyd Resin Exceptionally Durable Fast Drying Alkyd Paint
Fast Dry Alkyd Metal Primer
Alkyd Gloss Enamel
High Gloss Alkyd Aluminum Paint
Alkyd Baking Enamel

  

Quick Drying Modified Alkyd Based Primer

PRODUCT SPECIFICATIONS:

PRODUCT DESCRIPTION
Quick drying, modified alkyd based primers for general steel application.
General purpose primers with good rust resistance and low VOC. For
industrial use and shop application. Can be topcoated with enamel,
waterbase, and in some applications, urethane coatings.
FEATURES
• Quick drying
• Good rust resistance
• Interior/Exterior
• Low VOC
• Red brown color
• Low gloss

PRODUCT DATA
Description Results
Vehicle Type.................................... Modified Alkyd
Colors.............................................. Red, Brown & Gray
Gloss............................................... 0 to 10 on 60o Meter
VOC................................................ under 4 g/L (3.5 lbs/gal)
Weight/Gallon.................................. 11.3 pounds
Solids by Weight.............................. 72%
Solids by Volume............................. 48%
Viscosity.......................................... 40-50 seconds Zahn 2
Flash Point ..................................... 52o F
Freight Classification....................... Paint, Flammable
Packaging....................................... 5, 55 & 275 Gallon
APPLICATION DATA
Description Results
Application....................................... Spray, Brush or Roll
Recommended Thickness............... 1.0 - 1.5 mils DFT
Dry Time @ 77oF, 50% RH
To Touch...................................... 30 minutes
To Recoat.................................... 2 hours Note: Thicker films or
colder temperatures may require
a longer time to dry.
Coverage......................................... 770 sf/gal at 1.0 mil DFT
Thinner............................................ Acetone, TBAc or Oxsol to maintain
VOC. Xylene or HJ53 if VOC is
not an issue.
Clean Up......................................... Acetone, TBAc or Aromatics per
VOC requirements.
The technical specifications for this data sheet are based on product
Air Dry Red Oxide.
EQUIPMENT RECOMMENDATIONS
Listed below are general guidelines for the application of this product.
Job site conditions may require modifications to these guidelines to
achieve the desired results.
BRUSH & ROLL: Apply with synthetic brush or roller of appropriate
size and/or nap for the surface being painted. Avoid excessive
brushing. Always work to a wet edge. Do not touch up until dry. Do
not apply when surface temperature is below 45oF.
SPRAY APPLICATION (General): Mix thoroughly before use. Do not
apply when surface temperature is below 45oF. See the equipment
manufacturers instructions for recommended pressures, tip sizes and
cap sizes. May be applied by Conventional, Airless and Air Assisted
Airless systems.
GENAL SURFACE PREPARATION
All surfaces must be sound, dry, clean and free of oil, dirt, grease, wax,
mildew, loose or flaking paint and other foreign matter. Glossy surfaces
in good condition should be sanded before application.
DIRECTIONS FOR USE
TINTING: Do not tint.
THINNING: Exempt solvents such as Acetone, TBAc or Oxsol should
be used to maintain VOC. If the user has no VOC requirement, Xylene
or HJ53 may be used. For airless application these products may be
applied as is. For air assisted airless, conventional or HVLP application,
thinning may be required. Generally, 5-% thinner will meet viscosity
requirements for these applications. The exempt solvents will require
the higher end of this range and the non-exempt solvents the lower
end of this range. Greater reduction will be required when the application
changes from air assisted airless to conventional and then HVLP
equipment. Specific reduction instructions should be experimentally
determined at the point of use. Carefully read and observe all warnings
and instructions on the coating and thinner labels.
APPLICATION: Mix thoroughly before use.
DRYING TIME: Under normal conditions, 77oF and 50% or less relative
humidity, these primers will dry in 30 minutes. Higher humidity, lower
temperatures and thicker films will result in slower dry times.
CLEAN UP: Acetone, TBAc, Oxsol, Xylene or HJ53 as applicable.
HEALTH AND SAFETY
Read the Material Safety Data Sheet (MSDS) and container labels for
detailed health and safety information. This product is intended for
industrial use by properly trained professional applicators only.
The information, data and suggestions contained herein are believed to be reliable, based upon our knowledge and experience; however, it is expressly declared that Seller does not Buyer must make its own determination of the suitability of any product for its use, and the completeness of any information contained
herein. Nothing contained herein shall be construed to constitute inducement or recommendation to practice any invention covered by any patent without authority from the owner of
the patent.

 



Contact Us
 
Honest Joy Coating & Paint. All rights reserved.