Quick Drying Phenolic Modified Alkyd Based Primers Supplier in China
Quick Drying Phenolic Modified Alkyd Based Primers paint coating manufacture Shenzhen China  
Home About Us Products Contact Us

 

 




Honest Joy Coating & Paint
Phenol coating

VOC Compliant Phenolic Coating
Marine Spar Varnish
Rust Inhibitive Phenolic Modified Alkyd Primer
Phenolic Primer

Pigmented Short Phenolic Modified Alkyd Primer
Phenolic Two Component Epoxy Coating
Phenolic Modified Primer
Phenolic Heavy Duty Gym Floor Finish
Phenolic Alkyd Metal Primer
Two-Component Amine Adduct Crued Phenolic Epoxy Paint

Superior Solvent Chemical and Elevated Temperature Resistance Phenolic Coating
Quick Drying Phenolic Modified Alkyd Based Primers
Epoxy Phenolic Topcoat

Reinforced Hybrid Epoxy Phenolic Lining
Quick Drying Phenolic Modified Alkyd Based Primers
Two-Component Amine Adduct Crued Phenolic Epoxy Paint
Moisture Tolerant Lining
Baking Cross-Linked Epoxy-Phenolic Coating
Air Dry Phenolic Coatings

  

Quick Drying Phenolic Modified Alkyd Based Primers

PRODUCT SPECIFICATIONS:

PRODUCT DESCRIPTION
Quick drying, phenolic modified, alkyd based primers for
general steel application. Non-lifting general purpose primers
with very good rust resistance. For industrial use and shop
application. For applications requiring low HAP coatings and
low VOC (under 2.8 VOC). Can be topcoated with enamel,
waterbase and urethane topcoats.
FEATURES
• Quick drying
• Very good rust resistance
• Interior/Exterior
• Low VOC
• Low solvents
• Non lifting
• Resists topcoat strike in
PRODUCT NUMBS & COLORS
• HJ-077 Multipurpose Primer White
• HJ-051 Multipurpose Primer Red
• HJ-030 Multipurpose Primer Gray
PRODUCT DATA
Description Results
Vehicle Type.................................... Phenolic Modified Alkyd
Colors White, Red & Gray
Gloss............................................... 0- on 60o Meter
VOC................................................ under 336 g/L (2.8 lbs/gal)
Weight/Gallon.................................. 11.76 pounds
Solids by Weight.............................. 75%
Solids by Volume............................. 56%
Viscosity.......................................... 30-40 seconds Zahn 3
Flash Point ..................................... 40o F
Freight Classification....................... Paint, Flammable
Packaging....................................... 1, 5, 55 & 275 Gallon
APPLICATION DATA
Description Results
Application Conventional, Airless, Air Assisted
Airless Spray & HVLP, Brush &
Roll
Recommended Thickness............... 1.5 - 2.0 mils DFT
Dry Time @ 77oF, 50% RH
To Touch...................................... 30 minutes
To Recoat 2 hours Note: Thicker films or
colder temperatures may require
a longer time to dry.
Coverage......................................... 876 sf/gal at 1.0 mil DFT
Thinner
Spray Acetone, TBAc or Oxsol to maintain
VOC. Xylene or HJ53 if VOC is
not an issue.
Brush/Roll Oxsol to maintain VOC. HJ53 if
VOC is not an issue.
Clean Up Acetone, TBAc or Aromatics per
VOC requirements.
The technical specifications for this data sheet are based on
product HJ-077. For information on other colors in this series,
see the Color Table within this document and consult the
Material Safety Data Sheet for that product.
CURED FILM PFORMANCE


Description

Test Method

Results

Cleveland Humidity/Cold Roll

ASTM 4585

2,000 plus hours,

 

 

no effect

Salt Fog 2.0 DFT/Cold Roll

ASTM B117

500 - 1,000 hours,

 

D1654

no effect

Salt Fog 4.0 DFT/Cold Roll

ASTM B117

1,500 - 2,000

 

D1654

hours, no effect

EQUIPMENT RECOMMENDATIONS
Listed below are general guidelines for the application of this
product. Job site conditions may require modifications to these
guidelines to achieve the desired results.
BRUSH/ROLL: Mix thoroughly before application. Apply with
synthetic brush or roller of appropriate size and/or nap for
the surface being painted. Do not apply when the surface/air
temperature is below 45oF.
SPRAY APPLICATION (General): May be applied by Conventional,
Airless and Air Assisted Airless systems. See the equipment
manufacturers instructions for recommended pressures,
tip sizes and cap sizes.
GENAL SURFACE PREPARATION
All surfaces must be sound, dry, clean and free of oil, dirt,
grease, wax, midew, loose or flaking paint and other foreign
matter. Glossy surfaces in good condition should be sanded
before application.
DIRECTIONS FOR USE
TINTING: Do not tint.
THINNING: Exempt solvents such as Acetone, TBAc or
Oxsol should be used to maintain VOC. If the user has no
VOC requirement, Xylene or HJ53 may be used. For airless
application these products may be applied as is. For air
assisted airless, conventional or HVLP application, thinning
may be required. Generally, 5-% thinner will meet viscosity
requirements for these applications. The exempt solvents
will require the higher end of this range and the non-exempt
solvents the lower end of this range. Greater reduction will be
required when the application changes from air assisted airless
to conventional and then HVLP equipment. Specific reduction
instructions should be experimentally determined at the point of
use. Carefully read and observe all warnings and instructions
on the coating and thinner labels.
APPLICATION: Mix thoroughly before use.
DRYING TIME: Under normal conditions, 77oF and 50% or
less relative humidity, these primers will dry in 30 minutes.
Higher humidity, lower temperatures and thicker films will result
in slower dry times.
CLEAN UP: Acetone, TBAc, Oxsol, Xylene or HJ53 as applicable.
HEALTH AND SAFETY
Read the Material Safety Data Sheet (MSDS) and container
labels for detailed health and safety information. This product
is intended for industrial use by properly trained professional
applicators only.

 



Contact Us
 
Honest Joy Coating & Paint. All rights reserved.