Rust Inhibitive Phenolic Modified Alkyd Primer Supplier in China
Rust Inhibitive Phenolic Modified Alkyd Primer paint coating manufacture Shenzhen China  
Home About Us Products Contact Us

 

 




Honest Joy Coating & Paint
Phenol coating

VOC Compliant Phenolic Coating
Marine Spar Varnish
Rust Inhibitive Phenolic Modified Alkyd Primer
Phenolic Primer

Pigmented Short Phenolic Modified Alkyd Primer
Phenolic Two Component Epoxy Coating
Phenolic Modified Primer
Phenolic Heavy Duty Gym Floor Finish
Phenolic Alkyd Metal Primer
Two-Component Amine Adduct Crued Phenolic Epoxy Paint

Superior Solvent Chemical and Elevated Temperature Resistance Phenolic Coating
Quick Drying Phenolic Modified Alkyd Based Primers
Epoxy Phenolic Topcoat

Reinforced Hybrid Epoxy Phenolic Lining
Quick Drying Phenolic Modified Alkyd Based Primers
Two-Component Amine Adduct Crued Phenolic Epoxy Paint
Moisture Tolerant Lining
Baking Cross-Linked Epoxy-Phenolic Coating
Air Dry Phenolic Coatings

  

Rust Inhibitive Phenolic Modified Alkyd Primer

PRODUCT SPECIFICATIONS:

PRODUCT DESCRIPTION:
HJ-1909 is a rust inhibitive, phenolic modified alkyd primer, designed as a shop coat or field primer for structural steel and
other metal substrates. It has been specifically formulated for compatibility with Fireproofing materials,
strong solvent base paints and mastics, which may lift or blister other primer coatings.
RECOMMENDED USES:
HJ-1909 is recommended for use whenever a top quality metal primer is required. Primary applications are for installations to
be fireproofed with solvent based fireproofing coatings or mastic systems such as HJ-180 when such fireproofing will
be exposed to weathering, humid or corrosive environments.
PHYSICAL PROPTIES:
DRYING TIME: Air Dry Ð 15 minutes. WEIGHT/GALLON: 11.80 to 12.00 lbs.
RECOAT: Two hours between coats. SOLIDS BY WEIGHT: 66% ± 3%
PACKAGING: 1 gallon, 5 gallon and SOLIDS BY VOLUME: 60% ± 3%
55-gallon containers. COVAGE: 962 - 3 sq. ft. per gallon
COLOR: Red WET FILM THICKNESS: 2.00 - 5.0 Mils
GLOSS: Flat DRY FILM THICKNESS: 1.0 - 3.0 Mils
SOLVENT: Aromatic Solvents VISCOSITY: 40 - 50 sec. #4 Zahn Cup
FLASH POINT (TCC): 58û F (14û C)
APPLICATION:
Recommended Thickness: Surface profiles and porosity should be considered when determining coverage rates. For use
under normal interior conditions, apply 1 to 1-1/2 mils DFT at a theoretical coverage rate of 962 to 641 square feet per gallon.
For corrosive or exterior exposures, apply at 2 to 3 mils DFT at a theoretical coverage rate of 481 to 3 square feet per
gallon. Application may be made by brush, roller or spray gun using standard equipment and techniques.
Surface Preparation: Surface preparation should follow the recommendations of the .
In general, standard instructions for painting metal surfaces apply: Be sure surfaces are clean of all dust, rust, mill scale,
grease, oil, or other foreign residue thatmay impair adhesion. Sandblasting is required when the surface is encrusted with
rust, scale or other bond inhibiting residue not readily removed by hand or chemical means. In areas where sandblasting is
not permitted or feasible, power cleaning for steel (SSPC-SP3-63) is recommended.
Thinning: For brush application, dilute 4 parts HJ-1909 with one part high flash naphtha. For spray application dilute 4
parts HJ-1909 with one part toluene, xylene, or similar aromatic solvents.
HJ-1909 is a rust inhibitive, phenolic modified alkyd
primer, designed as a shop coat or field primer for structural
steel and other metal substrates. It has been specifically
formulated for compatibility with
Fireproofing materials, strong solvent base paints and
mastics, which may lift or blister other primer coatings.
HJ-1909 is recommended for use whenever a top quality metal
primer is required. Primary applications are for installations
to be fireproofed with solvent based fireproofing
coatings or mastic systems such as HJ-180 when
such fireproofing will be exposed to weathering, humid or
corrosive environments.
Recommended Thickness: Surface profiles and
porosity should be considered when determining coverage
rates. For use under normal interior conditions, apply 1 to
1-1/2 mils DFT at a theoretical coverage rate of 962 to 641
square feet per gallon. For corrosive or exterior exposures,
apply at 2 to 3 mils DFT at a theoretical coverage rate of
481 to 3 square feet per gallon. Application may be
made by brush, roller or spray gun using standard
equipment and techniques.
Surface Preparation: Surface preparation should follow
the recommendations of the Steel Structures Painting
Council. In general, standard instructions for painting metal
surfaces apply: Be sure surfaces are clean of all dust, rust,
mill scale, grease, oil, or other foreign residue thatmay
impair adhesion. Sandblasting is required when the surface
is encrusted with rust, scale or other bond inhibiting residue
not readily removed by hand or chemical means. In areas
where sandblasting is not permitted or feasible, power
cleaning for steel (SSPC-SP3-63) is recommended.
Thinning: For brush application, dilute 4 parts HJ-1909
with one part high flash naphtha. For spray application
dilute 4 parts HJ-1909 with one part toluene, xylene, or
similar aromatic solvents.
APPLICATION (cont.):
Dry Time: HJ-1909 is a fast-drying primer. Best results require at least 48-72 hours of curing time prior to overcoating
with heavy-bodied mastics. Allow a minimum drying time of 4 hours at room temperature if overcoating with a thinner paint
film such as HJ-107A.
Clean-up: Clean brushes, rollers and spray equipment promptly with toluene, xylene or similar aromatic solvents.
Storage: Store in tightly closed containers. Keep between 40-90û F (4-32û C)
Packaging: 1,5, & 55 gallon containers.

SAFETY PRECAUTIONS:
HJ-1909 Primer contains flammable solvents. Never apply material near open flame or excessive heat. Proper ventilation
should be provided especially in enclosed areas. Avoid prolonged breathing of vapor and repeated contact with skin. For
safety and health information on HJ-1909, please refer to our current Material Safety Data Sheet.
Dry Time: HJ-1909 is a fast-drying primer. Best results
require at least 48-72 hours of curing time prior to
overcoating with heavy-bodied mastics. Allow a minimum
drying time of 4 hours at room temperature if overcoating
with a thinner paint film such as HJ-107A.
Clean-up: Clean brushes, rollers and spray equipment
promptly with toluene, xylene or similar aromatic solvents.
Storage: Store in tightly closed containers. Keep between
40-90û F (4-32û C)
Packaging: 1,5, & 55 gallon containers.

HJ-1909 Primer contains flammable solvents. Never
apply material near open flame or excessive heat. Proper
ventilation should be provided especially in enclosed areas.
Avoid prolonged breathing of vapor and repeated contact

 



Contact Us
 