Water Borne Acrylic Protective Coating Supplier in China
Water Borne Acrylic Protective Coating paint coating manufacture Shenzhen China  
Home About Us Products Contact Us

 

 




Honest Joy Coating & Paint
Waterborne Coating

Waterborne Satin Enamel
Water-Borne Premium Quality Acrylic Primer
Water-Borne High Performance Interior Acrylic Primer Undercoat
Two-Part Water-Borne Linear Polyurethane Enamel

Water-Borne Epoxy Primer
Water Reducible Urethane Primer
Water Reducible Enamel
Water Miscible Epoxy Coating
Water Borne Inorganic Zinc Rich Silicate Primer
Two-Component Water-Borne Epoxy Primer

Water Based Two-Component Epoxy Polyamide Finish
Water-Borne High Performance Acrylic Metal Primer
Water Based Gloss Epoxy Enamel

Urethane Modified High Solids Water Borne Coating
Water-Borne High Performance Acrylic Metal Primer
Water Borne Acrylic Protective Coating
Arylic Thermo Plastic Waterbase Finish
Self-Levelling Epoxy Flooring Water Borne
Acrylic Water borne Paint Eggshell Waterborne Interior Paint
Environmentally Friendly Waterborne Metal Primer
Fast Drying Interior Exterior Primer
Acrylic Water borne Paint
High Gloss Waterborne Aliphatic Polyurethane Enamel

  

Water Borne Acrylic Protective Coating

PRODUCT SPECIFICATIONS:

Description
Intended Uses
Practical
Information for
HJ-777
Regulatory
Data
Single pack heavy duty, high build water borne acrylic emulsion which provides
excellent pliability and elasticity, allowing appreciable substrate movement without
cracking.
HJ-777 has been designed to give excellent resistance to gas diffusion and
water vapour transmission.
For application to a wide range of substrates, including off form concrete and
cement rendered structures, where a tough, flexible, weatherproof finish is required.
Other typical uses include:
Coating internals and externals of silos and grain storage sheds to provide gas tight
seals and heat reflectance
Roof refurbishment
Colour White. Colours manufactured to order
Gloss Level Low sheen
Volume Solids 52%
Typical Thickness 100-300 microns (4-12 mils) dry equivalent to 190-580
microns (7.6-23.2 mils) wet
Theoretical Coverage 2.6 m2/litre at 0 microns d.f.t and stated volume solids
106 sq.ft/gallon at 8 mils d.f.t and stated volume solids
Practical Coverage Allow appropriate loss factors
Method of Application Airless spray, Brush orRoller
Drying Time
Overcoating Interval
recommended topcoats
Temperature Touch Dry* Hard Dry* Minimum Maximum†
10°C (50°F) 3 hours 12 hours 12 hours Extended
15°C (59°F) 2 hours 8 hours 8 hours Extended
25°C (77°F) 1 hour 4 hours 4 hours Extended
40°C (104°F) 30 minutes 2 hours 2 hours Extended
* Drying times are dependent upon ambient conditions. The figures quoted above
have been determined at the quoted temperature and 60% relative humidity.

Flash Point >101°C (>214°F)
Product Weight 1.35 kg/l (11.3 lb/gal)
VOC 542 g/l (calculated)
43 g/l (water reduced)
Surface
Preparation
All surfaces to be coated should be clean, dry and free from contamination. Prior to
paint application all surfaces should be assessed and treated in accordance with
:1992. Strict adherence to all cleanliness standards is essential for
application of water based coatings.
Steel
HJ-777 should always be applied over a recommended anti-corrosive coating
scheme. The primer surface should be dry and free from all contamination, and
HJ-777 must be applied within the overcoating intervals specified (consult the
relevant product data sheet).
Galvanised
Degrease to SSPC-SP1 and remove any white zinc corrosion products by hand
abrasion cleaning. Weathered galvanised steel should have areas of red rust wire
brushed to remove loose rust and spot primed with HJ-880 or HJ-766 and
degreased as above.
Concrete
Concrete should be cured for a minimum of 28 days prior to coating. The moisture
content of the concrete should be below 6%. All surfaces should be clean, dry and
free from curing compounds, release agents, trowelling compounds, surface
hardeners, efflorescence, grease, oil, dirt, old coatings and loose or disintegrating
concrete. All poured and pre-cast concrete must also be swept blasted (preferred)
or acid etched to remove laitence. Large cracks should be filled with a suitable filler.
When coating new tilt formed concrete, an epoxy sealer must be employed.
Application
Mixing This material is a one component coating and should always be
mixed thoroughly with a power agitator before application.
Mix Ratio Not applicable
Working Pot Not applicable
Life
Airless Spray Recommended - Tip range 0.48-0.64 mm (19-25 thou)
- Total output fluid pressure at spray tip not
less than 211 kg/cm2 (3.000 p.s.i.)
- Do not thin
Air Spray Not recommended
(Pressure Pot)
Brush Suitable for small Typically 75 microns (3 mils) can be
areas achieved
Roller Recommended Typically 75 microns (3 mils) can be
achieved
Thinner Water
Cleaner HJ-8809
Work Stoppages Thoroughly flush all equipment with HJ-8809. All
unused material should be stored in tightly closed containers.
Partially filled containers may show surface skinning and/or a
viscosity increase of the material after storage. Material should be
filtered prior to use.
Clean Up Clean all equipment immediately after use with water followed by
HJ-8809.
It is good working practice to periodically flush out spray
equipment during the course of the working day. Frequency of
cleaning will depend upon amount sprayed, temperature and
elapsed time, including any delays.
All surplus materials and empty containers should be disposed of
in accordance with appropriate regional regulations/legislation.
Product
Characteristics
Apply by airless spray. Thoroughly flush equipment with HJ-835
thinner followed by water prior to use. To obtain maximum edge protection and film
build, airless spray application is recommended. Application by other methods, e.g.
brush or roller, may require more than one coat.
If applying HJ-777 by brush or roller, material should be flowed on rather than
brushed out.
Application by brush or roller will usually not result in a smooth film.
With all water based coatings careful control of application conditions is required to
ensure good long-term performance. have available
a set of working procedures relating to the application of water borne paints which
are available on request.
The following basic parameters must be adhered to:
HJ-777 must be protected from freezing at all times during storage.
The minimum steel temperature for application must be above 10°C (50°F), and be
at least 3°C (5°F) above dew point.
The relative humidity should be lower than 70% otherwise drying and overcoating
times will be severely extended.
Good airflow is essential around the object being painted [minimum air speed
0.1m/sec (4 inches/sec)].
Minor areas that are difficult to ventilate should be brush applied to prevent overapplication.
Application below the minimum film forming temperature (M.F.F.T.= 5°C) of the
coating and/or poor ventilation will result in poor film coalescence and will result in
a powdery cracked film that will require removal and re-application.



Safety Precautions
This product is intended for use only by professional applicators in industrial
situations in accordance with the advice given on this sheet, the Material Safety Data
Sheet and the container(s), and should not be used without reference to the
Material Safety Data Sheet (MSDS) which has
provided to its customers.
All work involving the application and use of this product should be performed in
compliance with all relevant national, Health, Safety & Environmental standards and
regulations.

Pack Size
litre unit litres in a litre steel container
5 gallon unit 5 gallons in a 5 gallon steel container

Shipping Weight

litre unit 28.5 kg (62.7 lb)
5 gallon unit 26.9 kg (59.3 lb)
Storage
Shelf Life 24 months minimum at 25°C (77°F). Subject to re-inspection
thereafter. Store in dry, shaded conditions away from sources
of heat and ignition. Protect from freezing at all times during

 



Contact Us
 